Every year, roughly 10 million American homes get a new water heater. Luke Winston-Almanzar, co-founder and CEO of Reservoir, puts the heat pump share at about 2%.

That gap framed a panel Eric moderated at the Heat Pump Summit with three Massachusetts founders building heat pump water heaters three different ways: Michael Rigney of Cala Systems, Luke of Reservoir, and Bruce Hiles of Smart Solar. The question underneath it: are heat pump water heaters reliable enough to put your name on, and how do you sell one when the customer's old tank just failed?

Most water heaters get replaced in a hurry, by whoever answers the phone

Bruce, who founded New England Solar Hot Water, described the replacement market. The tank leaks. The homeowner calls a plumber. The plumber picks up whatever is on the distributor's shelf, usually the same kind of unit that just failed. Even homeowners who have just electrified their heating often keep the old water heater, because it isn't part of what their mini-split installer offers.

Luke added that water heaters fail at the worst possible moment, and the swap takes an afternoon.

Reliability is the elephant in the room, and the panel said so

Michael made an admission early on. A lot of contractors have had trouble with heat pump water heaters over the last decade, and he said any honest conversation about the category has to start there. He called it the elephant in the room, and said it's improving.

Cala manufactures in Wilmington, Massachusetts, delivers to its Northeast contractors within 24 hours, and some contractors keep units in stock for same-day swaps. Michael said remote monitoring has been one of the biggest satisfaction points, because the contractor can see what the compressor is doing without rolling a truck. Cala reports that 93% of the energy going into its fielded units comes from the heat pump, not the resistance elements.

Reservoir installs its own systems through a plumbing company it owns, and sends its own team when something goes wrong, including on jobs a partner installer sold. Bruce's answer is simplicity: Smart Solar uses a fixed-speed compressor and no electronic expansion valve.

Running out of hot water is the callback to design against

A contractor in the audience described the call installers dread. He replaced an oil-fired water heater with a heat pump unit, and the family started running out of hot water. His fix was to raise the tank temperature.

The panel agreed with the diagnosis. Luke said it can take five to six hours to heat a 50-gallon tank, so a unit that only reacts once the tank cools gets caught by a big morning draw.

Cala and Reservoir both use predictive controls that learn a household's schedule and heat ahead of demand, with a mixing valve so the tank can store water hotter. Bruce's answer is a bigger tank. Smart Solar's evaporator is a flat panel mounted outside, so the standard tank is 80 gallons and a 120 is available. He said many of his installs have never turned on the backup element.

Storing water hotter has a cost. Luke said corrosion runs several times faster at 150°F than at 120°F, which is why Reservoir uses a powered anode. Michael added thermal stress on the tank, and said Cala only overheats it when the household's pattern calls for it.

Time-of-use rates will arrive during the life of today's installs

Luke described a Massachusetts town where off-peak power costs about a tenth of the on-peak rate. A water heater that heats at 3 a.m. and coasts through the evening peak is working as a thermal battery. Michael said changing electricity rates are coming to Massachusetts and the Northeast in the next couple of years. A water heater installed this winter will likely still be running when they do.

The innovation in space heating has reached the water heater

Many of our listeners got into heat pumps because the technology kept getting better: variable-speed compressors, cold-climate performance, smarter controls. This panel shows the same thing happening to the water heater. Variable-speed compressors, predictive controls, remote monitoring, and new layouts like Smart Solar's outdoor panel are all installed in homes today.

For contractors building their business around heat pumps, that makes the heat pump water heater a natural adjacent product. You're already in the home for the heating job, and you've already earned the homeowner's trust. Adding the water heater raises the ticket on a job you've already won, and it puts you first in line when the old tank fails, ahead of whoever answers the emergency call.

 

Timestamps

[00:00] - Cold Open: Smarter Hot Water Heating

[02:48] - Meet the Panelists: The Future of Heat Pump Water Heaters

[06:53] - Why Hot Water Is a Major Home Electrification Opportunity

[11:40] - New Innovations in Smart Heat Pump Water Heaters

[20:10] - Split Systems, Cold-Weather Performance, and Efficiency

[23:05] - Business Models, Contractor Partnerships, and Market Adoption

[28:54] - Installation Challenges and Contractor Benefits

[34:35] - Audience Q&A: Cold Climates, Space Requirements, and Ducting

[46:19] - Smart Monitoring, Leak Detection, and Connectivity

[50:13] - Thermal Batteries, Time-of-Use Rates, and Grid Flexibility

 

Follow the Guests:

  • Bruce Hiles

 

  • Luke Winston-Almanzar

 

  • Michael Rigney:

 

Transcript:

00:00:00.000 — 00:00:39.080 · Speaker 1

We actually have three electric resistance elements built into Reservoir. We have an inline booster heater built into it, so we can actually heat the marginal amount of hot water, as opposed to the two electric resistance elements that are inside the tank, where you try to heat the entire tank all at once.

 

We can heat just marginal amounts of hot water. So let's say you're in the shower. It's starting to get lukewarm. Plan my name really quick. I'm just starting to get lukewarm. We can run the booster heater. Make sure you finish your shower without destroying the efficiency. The whole system by trying to heat 50 gallons in a tank.

 

But that's actually a lot of the whole point of, like, why we have our adaptive algorithm, the extra resistance elements, but then we also have party mode. And so we can get 150 gallons out of even of the tank is just 50 gallons.

 

 

Here on the Heat Pump podcast, we mostly talk about heat pumps for space heating. But the second biggest energy use in the home is hot water at the Heat Pump Summit this year, my good friend and co-founder Eric Fitz moderated a panel with the CEOs of three companies, all based in Massachusetts, that are building a new generation of heat pump water heaters. Michael. Bruce and Luke are all incredibly candid about what's happening in the market. If you're at all interested in building heat pump water heaters into your offering. This is an awesome episode to get up to speed on the latest and greatest innovations in that space. One thing to know Eric's audio track got messed up and we're not sure how. We tried to fix it, but couldn't. And the three panelists sound is absolutely perfect. So we decided to release this episode anyway because it's such a great discussion on a very interesting topic. Eric doesn't talk that much anyway. He's the moderator. It's mostly about the panelists, but if you're a regular listener to this podcast, you will know that on a typical day, Eric does not sound like Alvin from Alvin and the Chipmunks.

 

So forgive us for Eric's audio and enjoy the episode. Before we start, a quick plug. Eric and I are each teaching a webinar with Southern California Edison, the large utility that are open to anyone. On Tuesday, December 8th, I'm teaching high performance heat pump sales and marketing. It's the full sales process from how to set up your website all the way through, giving a quote and a referral. Everyone who attends gets a free toolkit that has a whole bunch of good stuff, like an intake call script and a comfort survey. Then on Tuesday, December 15th, Eric is teaching his course designing heat pump retrofits that won't come back to haunt you. That one covers manual J inputs, static pressure, and manual S for variable capacity equipment. Both run 9 to 11 Pacific, noon to two eastern. The registration links are in the show. Notes. We'd love to see you there. And if you're getting anything out of this show like us, subscribe. Leave us a review. All right, on to Eric's panel on heat pump water heaters.

 

 

00:00:43.160 — 00:01:55.960 · Speaker 2

All right. Welcome everybody. Super excited for this conversation this morning. We've got excellent panel lined up here on hot water reimagines hot water. Here's in the homes hidden opportunity I am Eric Fitz, I'm co-founder of Amply. I'm also co-host of the Heat Pump podcast. I'm also a huge fan of heat pump waters and I'm honored to help moderate this panel.

 

Today I will do super short introductions of our panelists and then we'll have a chance to introduce themselves. This conversation today we got some prepared questions, but we also want to make interactive. So if you have questions, feel free to stand up at any point of your conversation. There's a bike ride here in the center of the room that you can ask your question.

 

If it's challenging at all in the room, you could just raise your hand, yell it out. I'll restate the question and we can engage that way as well. All right, so without any further ado, we've got Bruce Hiles in here. He is the founder of New England Solar Hot Water (NESHW) and Smart Solar. We've got Luke Winston-Almanzar out there on the other end.

 

He's co-founder and CEO of Reservoir. And we got Michael Rigney, co-founder and CEO of Cala. Welcome and thank you for joining this panel.



00:01:56.960 — 00:01:57.920 · Speaker 3

Thanks for having us.



00:01:57.960 — 00:02:53.680 · Speaker 2

Yeah. So let me just do a little step and then we'll get in some intros. So water heaters are often the most overlooked device appliance in the home. They use almost 20% of energy in the average residential building. Not a full lock has changed in the last hundred years with hot water gears. And I think what these three folks are doing really represents a lot of the major innovation in the space in particular.

 

So things are changing fast. We want to get into a lot of those changes in machines. What are some of the challenges? And there's a lot of interesting opportunities if we make cut water, heating, more intelligence, participating in grid events, integrating with other devices, changing configuration and equipment.

 

That's really cool stuff to purchase. So let's do some fire retros. Let's start with Luke, because I'm looking at you right here, tall Snake. That's great. Do we couple says just tell you a couple sentences.



00:02:53.720 — 00:04:25.440 · Speaker 1

Good morning everyone. I guess we got to start with hot water because you get to start the day with a hot shower. So my name is Luke. I'm CEO and co-founder of Reservoir Wear, a Boston based company. We design, we manufacture, and we install predictive heat pump water heating system with an integrated hydronic control system, also called the Reservoir we're operating in throughout New England in multiple states.

 

At this point in a past life, I helped build another smart device company called FormLabs. It is a 3D printing space. We went from zero to a multi-billion dollar company. I wanted to bring my skills and my experience to help home electrification just get easier, more affordable, and honestly, just more awesome.

 

I'm so excited to tell you more about it. Hey everybody! Michael Rigney, the CEO and co-founder of Cala Systems. We're based just north of Boston, and we manufacture a smart heat pump water heater that learns and adjusts each home. I'm sure we're going to talk a lot about that over the course of the next hour.

 

How it works. We launched it a year ago. We're selling it in 36 states. So we started here in Massachusetts. We manufacture in Wilmington. So just about 40 miles away from here in a past life. In terms of my own background, I grew up in a family that does contracting, spent my summers painting houses. It was a big part of my background and then started a company that did financial services, financial for contractors.

 

So I really loved this space, have been in it, and that's been a long time in the energy space. And it's really the intersection of energy and what's going on here with hot water. That drew me into founding the company. Bruce from Smart Solar. We’re located south of Boston.



00:04:25.480 — 00:04:46.480 · Speaker 4

I'm a bit of an outlier with respect to my colleagues up here, and that our system is a split system as opposed to a unitary system. A split heat pump water heater system gets its heat from, not the conditioned space. In our case, it gets it from outside. In my past life, I founded New England Solar Hot Water.

 

So for 20 years I've been in this space and we've transitioned from hot water systems, panels on the roof to heat pump water heaters.



00:04:46.520 — 00:04:58.150 · Speaker 2

Awesome. Let's get right into it.. Why should anyone care about that water? Let's set the stage for why should a homeowner, why should anybody care about hot water? Why is this a big deal? Bruce, why don't you start?



00:04:58.830 — 00:05:52.630 · Speaker 4

20% or more of the energy use in a home is hot water. In our case, everybody wants to electrify. We're trying to address a market that's actually being reset, right. So right now the market channel is the market is dominated by three very large players Smith Bradford, white. They have an existing channel. And that channel is they sell to distributors wholesalers.

 

And then somebody at home has a leaking water heater. They call the plumber. And the plumber picks up a box from a distributor. And they generally get the same hot water heater installed because they have no hot water. So the three of us are trying to break that cycle to some extent or another. People want to electrify.

 

They want to put mini splits in. Oftentimes they put mini splits in and they end up with the same hot water heater that they started with because it's difficult to part of the offerings from mini split installers. That's all changing very quick. We're working our way in similar ways, in different ways of three of us, but mostly the market is being reset and people are starting to care and their needs aren't being met by the existing supply, distribution and installation chain.



00:05:52.710 — 00:05:59.150 · Speaker 2

That's big on the energy side. What other reasons do we care about hot water, anymore from. Yeah, that. Go ahead. Yeah.



00:05:59.310 — 00:07:09.990 · Speaker 1

I guess the way I put it is there's three certainties in life. One is death. One is taxes, the other is your water heater is going to fail. It'll probably fail at the worst possible moment when you have a new kid. It's Christmas at Thanksgiving. That stuff when it also uses 20% of home energy. It's this huge use of energy in the home that most people actually don't realize.

 

It's the second biggest use of energy in the home. And so when you have something that's that high of a replacement rate using that much energy, it is the biggest major piece of energy infrastructure in your house that's replaced at this rate every year in the United States, there's 10 million water heaters replaced and you replace them in the morning.

 

You can replace them in an afternoon. And so you can make a huge impact on someone's house because it's 20% of their energy. The reason I actually started Reservoir is because I realized I was using more energy to heat my water than it takes to drive an electric car, and so in a morning or an afternoon, you can impact someone's energy bills.

 

You can help protect their house. I'll tell you about some of the protection features that Reservoir actually has, but you can also end up helping balance the grid. It's a huge market to actually get into, and I think a lot of people have been hesitating to fully electrify. And that's why I'm excited to be up here with my colleagues here to help get you guys excited about it.

 

I leave a slightly different answer.



00:07:09.990 — 00:07:43.790 · Speaker 3

And that is that some people really care and a lot of people don't yet. And that's embedded in some of what you're saying about it being a replacement for last minute. But there's a segment of the population that really wants to electrify their homes. And I think that many folks in the audience let me stop being a quick poll.

 

Are most of you contractors were here at the Heat Pump Summit, so could you raise your hands if you're a contractor? Most of your contractors can. Anyone who's not a contractor, are you willing to shout out what you do just so we can on your no shy manufacture? Okay, we got some manufacturers. Okay? We've got a lot of contractors.

 

We got some manufacturers.



00:07:44.270 — 00:07:46.230 · Speaker 2

Your supervisor, Claire Rizal.



00:07:47.030 — 00:07:49.630 · Speaker 3

Okay. Massive. Awesome. So programs. Okay. Cool. Yeah.



00:07:49.630 — 00:07:52.470 · Speaker 2

We're forever short on the energy efficiency programs.



00:07:52.510 — 00:07:53.230 · Speaker 3

Awesome.



00:07:53.790 — 00:07:54.230 · Speaker 2

API designer.



00:07:54.230 — 00:09:35.110 · Speaker 3

API designer. Okay, so we've got some maybe call of roughly two thirds contractors and then some designers, programmers, the program designers for energy efficiency, excuse me. And utilities also. So we've got a segment of the whole community. And I think the our take on it at Cala is that there is a segment of the population that really cares.

 

And then there's a segment of the population that doesn't care that much, that may react only when their water heater fully breaks, or when their water heater starts to really get old and they are forced to pay attention to it. And they engage in the process in that way. But our view is that we want to make this category better for both of those communities.

 

And the way that we do that is by working with the contractors. So that call is available to the contractor to sell to both communities. We want to get the product out there and we want it to scale. Obviously, that's good for us, but it's Broadly good for every segment of the population, right? We're going to talk about how our products are different from what's out there.

 

We'll get into that, I'm sure, in the hour. But our focus is on, hey, let's go after both of those communities because they both need the benefits of this category. And I'll finish by saying, what's really critical in doing that is making sure that this is a great experience for the contractor. We shouldn't talk about people's water heaters without acknowledging that a lot of contractors have had trouble with them over the last decade.

 

Like, I was talking with the contractor out in the hallway, and he talks about the troubles he's had on the reliability front. I think that this is improving across the category, but it's a bit of the elephant in the room, and my intention is to definitely talk about that and how we think about that.



00:09:35.150 — 00:10:11.550 · Speaker 2

So we touch on a bunch of different topics within that question. I feel like this is a great point. Dig further into what's the innovation that is happening here around whether it's making it easy to install from a contractor perspective, de-risking improve the reliability of the equipment, whether it's the consumer experience.

 

There's a lot of those areas. You were each based on what's really changing now and what are people's. I'll say using my marketing or oh, we'll get there. But first, what's reality? What's really available today. And this really change prepares it yesterday. So why don't you. Sorry.



00:10:11.590 — 00:13:14.030 · Speaker 1

Yeah. Happy to. We don't have some, like, crazy new heat pump that we invented. We don't have some fancy new refrigerant out of a lab out of MIT at Reservoir. We're very much in the deployed to pump. There's, like, a lot of amazing technology out there. A lot of different companies have proven that you can take existing technology and combine it in very innovative ways, like whether it's Apple or whether my last company Form Labs.

 

And so what we see is this big chance to integrate existing technology in an intelligent way. And so what we decided to do was add intelligence, both so that we can get some more efficiency. We can get some more out of a heat pump, but so we can actually add a bunch more capability in our system. And so if you actually take a look at a Reservoir where you can see it being shown here, my colleagues are actually in the back and you can talk to them about it.

 

But if you look at a Reservoir, you can actually see like a typical heat pump water heater. Like I said, we didn't invent a brand new heat pump, water heater, heat pump, water heaters were actually invented in the 40s. What we did was we took a typical heat pump water heater. We add a predictive computer to it.

 

So Reservoir spends the first month in your house learning your behavior so it knows when you shower. It knows when you wash your dishes. Things like that. But it also knows when you step in the shower. And so we've actually integrated a variety of other components into the system which we call. If you actually look at the Reservoir, there's this really elegantly designed rectangular portion of the system.

 

And it has a hydraulic control system. So we actually have built in recirculation. We have ultrasonic flow meter. We have an integrated condensate pump. We have a variety of other sensors and actuators that can actually add a ton of value. And so like our philosophy is look, you're never going to go without hot water when your water heater fails, you're going to replace it.

 

And so you should make it do a lot more for your house. And so Reservoir. Ends up actually being like three products in one. One, it's a predictive water heater that can get you 150 gallons out of a 50 gallon tank, could deliver water to your faucet instantly. But then it's also the second product is it's actually a home plumbing security system.

 

Like a lot of other water heating systems, we've integrated automatic leak detection so it can automatically shut it off. But we can actually see further into your plumbing system than basically anything else out there. So you can see into your plumbing lines and see if you have a leak or if you left a faucet on.

 

We can actually sample your cold water and predict if your pipes are on the verge of freezing. And then we can actually ask you, hey, Michael, do you want us to pump warm water into your pipes or your pipes? No. Freeze. And the answer is usually yes. And then we could also automatically kill Legionella bacteria and other things like that.

 

And then finally, something I imagine we'll get to in a minute is just talking about the concept of a thermal battery. And so everything that we're actually doing, we're integrating a predictive computer, but with a bunch of other capabilities all in one very elegantly designed package. The second piece that we actually think is super important.

 

I hope we talk about this a little bit more is we're making it affordable. So we're actually doing things quite a bit different. We design, manufacture and we install the system. We think historically heat pump water heaters have been just they're efficient but they're too expensive. And so by being vertically integrated we actually can be cost competitive with almost anything on the market.

 

Hand it over to you guys.



00:13:14.590 — 00:13:17.710 · Speaker 2

I love that you are out there. How do you define animation for.



00:13:18.070 — 00:16:05.659 · Speaker 3

Yeah. So where we focused at Cala, how the product works is how do we ensure the number one thing that people want and that is and the contractor wants and needs. And we started there, which is how do we ensure that hot water is available and at times of peak demand, and that what you're actually doing is using the heat pump as opposed to the resistance elements.

 

And so core innovations to drive that are better data. Predictive controls, which both companies are doing, as you can tell. And I'll talk about how we do it and then better hardware to actually execute on that. So what does that mean? First we have a flow sensor. So we learn how each phone uses hot water.

 

We can also intake any information that makes sense whether pricing information, if they have a solar system on their roof to changing electricity rates, which we will have in Massachusetts and the northeast in the next couple of years. All of that information flows into a predictive algorithm that is continuously looking out into the future.

 

We license this from a national laboratory. It's the basis of predictive intelligence. And we're running on a machine not in the cloud. On each unit, we're running an accurate physical model of the water tank and the compressor. And we're predicting forward how much hot water is needed. What's the best way to actually do the heating.

 

Right. So that is based on breakthrough technology developed 30 years ago. That's how self-driving cars actually work. The same algorithm. So that's called predicted intelligence. None of that matters if you don't have the hardware to actually execute on a better planned strategy. So what does that mean?

 

That means we have a variable speed compressor. When you slow down the compressor in the water heating application, you actually make it up to 25% more efficient. And when you speed it up, you put more heat into the tank. And then we also have a mixing valve. The mixing valve allows us to control the temperature of the water in the tank, so we can control on our own without input from the schedule, etc..

 

How fast, when and to what temperature we heat the water. And the way to think about that is if you have better intelligence but don't have physical control, then it's like putting GPS on a hot air balloon or you'd like to go, but you can't actually get there. And so we've proven in the field works 93% of the energy going into our product, into Cala water heaters across the country is coming from the heat pump and two thirds of that.

 

Actually, it's more than that. Over two thirds of that is coming from the compressor. Operating at medium to slow speeds, and over 99.7% of all water draws are delivered at the right temperature. Why does this matter for contractors



00:16:06.660 — 00:16:42.500 · Speaker 3

callbacks? We're focused on making your business better when the customer is unhappy. You get a call when you have to deal with that call. What we found is it disrupts the contractor's business. We want your business to be Smith. We want your business to be profitable. We want you to be incredibly happy with the product.

 

We want your customers to be incredibly happy with the product. So our primary focus with the launch and the initial scale up has been delivering on the promise of what a heat pump water heater can and should actually give. All right, I'll stop there. I'm sure we'll come back to lots more stuff.



00:16:42.580 — 00:16:45.460 · Speaker 2

Sales and innovation and for our readers.



00:16:45.940 — 00:17:37.260 · Speaker 4

So our use case and our innovation, they fold together. Of course, our use case for a split heat pump water heater that gets its energy from outdoors as opposed to the conditioned spaces. Every place where a unitary or even a smart heat pump water heater won't work right? So if you don't have a basement, you don't have a room air volume that's sufficient to support an air source heat pump.

 

Then you look at a split heat pump water here like ours. Along the way, a couple other things happen. You'll hear there's a lot of talk about storage and thermal batteries and stuff like that. And here in that discussion is the presumption that heat pump water heaters heat very slowly. Right. It's not like a gas fired appliance, which can be almost an order of magnitude more heat generation.

 

In our particular architecture, our heat pump is physically separate from the tank. That means we can give you whatever size tank you want. So we don't have a lot of predictive controls because which is good because we're not that bright. But we will give you a bigger tank, right? So our standard size is an 80.

 

And we have the only 120 gallons.



00:17:37.340 — 00:17:37.540 · Speaker 1

From.



00:17:37.540 — 00:17:38.340 · Speaker 5

Texas or something.



00:17:40.100 — 00:18:04.660 · Speaker 4

We have the only 120 gallon Energy Star approved heat pump water heater. So the goal, of course, is to make sure that you never use your backup element. We have a backup element, but we also have a very large number of installations where it's literally never come on. So two advantages. We're taking our heat source.

 

All heat pumps need a heat source. We're taking our heat energy from outside. And our architecture allows us to give you a fundamentally bigger tank, which means you're not relying on the backup element in most cases at all.



00:18:04.700 — 00:18:27.020 · Speaker 2

And I think it's worth spending another moment just talking to more about the unique aspects of your eco water heater uses, not just this equipment. Outside, there's a bunch of other split pop art here where there's Outdoor Union with a compressor in it. You got something very different. You still have the equipment doing the pumping and moving and the refrigerant is inside.

 

But you're saying you've got an evaporator outside, is that right?



00:18:27.060 — 00:19:25.340 · Speaker 4

Exactly. So an evaporator for most heat pumps is a fan coil unit, right. So it's a radiator basically has a tremendous amount of surface area by virtue of the fact that it's that has fins on it and you need to blow air by it. Just as you can make an indoor unitary heat pump partner with that type of evaporator.

 

You can also make an outdoor. And my colleague has split heat pump water heater that does that. The limitation of that is cold, right? The refrigerant is generally very cold. And depending how you design that thin coil, it's going to frost up. When it frosts up, you need to put it in a reversing cycle or you need to kick over to resistance hot water heating, both of which are inefficient.

 

Our design is just a panel, right? Evaporator is just a panel. It doesn't rely on moving air, it just relies on convection. If it's in the sun, that's good. It doesn't have to be in the sun. In many cases, that panel can ends up in the bushes or in a few cases, on the bottom of a deck. Right. So it works by convection, which is moving air.

 

It'll frost up, it'll develop frost, but it'll keep going. The efficiency decreases when there's frost on the panel, but there's no defrost cycle. It just keeps going down to -20 Fahrenheit. That's our core innovation.



00:19:25.340 — 00:19:54.540 · Speaker 2

And so I heard a lot of different things you just talked about. You got so innovation around hardware. There's innovation around controls and observing different aspects different sources of data, whether that's happening inside the home or you're pulling in weather information you're also innovating on the business model.

 

So we've got Luke. You're doing your funny Burgundy integrated Michael and Bruce are you at where's your business model. And then how are you going into the hands of all of those companies?



00:19:54.580 — 00:20:59.660 · Speaker 3

Cala is available to contractors. We've got contractors here at the conference who are using installing it. And that's pathway number one. That's the dominant way that we sell. The second is that we do market to homeowners. And the reason we do that is that at this early stage in the market, there's people who really get it.

 

There's that segment. And it's what I mentioned before who are like, yeah, that's what it should be. Now we take those leads. We give them to our contractors, which is another benefit we bring to their business, which hand over leads to them. Right. And so this is common, of course, in the industry you all know this Mitsubishi does this.

 

Many manufacturers do this. So we want to bring high quality qualified leads that lead to that result in profitable sales for you and in many cases add on business. And so we've seen it works as well. So our view is that the way to scale in the industry is to take advantage of the contractor base that is out there that knows their local population, that knows what appropriate installation looks like for all the various home types across the country, etc. and then we accelerate that by making it available to homeowners as well.

 

Particularly at the early stage of getting it going.



00:20:59.700 — 00:22:04.180 · Speaker 4

So I started a few moments ago talking about how existing hot water heater replacement market is more or less broken. What the three of us have in common up here is that we're not selling through distribution for our model. It just doesn't work right. So, we're entirely vertically integrated. We're a manufacturer.

 

We use contract manufacturers overseas or distributor. And that we sell to distributors. And in 4 or 5 states right now, although we have product in many more states, the vast majority of our systems are in Massachusetts, probably half. And a majority of those. The company I'm affiliated with, New England Solar Hot Water, has installed those directly.

 

In our case, we generally advertise on the installation side, not on the smart solar side. But the installation company advertises heat pump water heaters generically because you can't advertise a split system because nobody knows what it is. A salesperson will visit virtually most of the time. Explain the benefits of both.

 

Most of the time they'll go for a split heat pump water heater, but we will honestly sell a conventional heat pump water heater. Not often, maybe one a week if that, and we haven't used Bradford White or AeroTherm. But the point is that the market doesn't understand split heat pump water heaters, perhaps that they don't yet understand smart heat pump water heaters.

 

Therefore, we need to take a hold of the entire process. The entire stack.



00:22:04.260 — 00:23:11.170 · Speaker 1

Yeah. So as you said, we're vertically integrated. A couple of reasons we do that. One, we think that the customer experience is absolutely paramount. We think some of the stop starts of heat pump water heaters have been because the customer experience has not been great. The contractor experience has not been great.

 

We also think it's super important that the all in cost of acquiring both the hardware as well as the installation, as well as removing the system, it just needs to be lower. We want to be competitive with everything else out there, not just other heat pump water heaters. And so we're also establishing is so Reservoir.

 

We are the best installers in the world for our own product. But that doesn't mean we shouldn't work together. We actually work with quite a few different home service contractors. We work with solar installers whose customers want to heat pump water heater. They want the most advanced heat pump water heater in the world.

 

We work with heat pump installers who also want that in different places, and we also work with plumbers and we make it worth your while and everything. And so we are able to provide an amazing cost, competitive customer experience for your customers. So that might not be for everybody in this room. But we do successfully work with quite a few different home service contractors, because sometimes the customer better than we do and we can collaborate and actually make an amazing experience.



00:23:11.170 — 00:23:22.490 · Speaker 2

So to follow in on that. So your most of your sales are from your home team, but it sounds like you have to partner with a contractor if you have a training program or certification.



00:23:22.770 — 00:24:11.850 · Speaker 1

We always do our own installs, so we have a fully licensed, wholly owned plumbing company in Massachusetts. We'll have some more announcements soon about some other places that we're about to have some. But what we do is so one of our partnership, we work with forge. I imagine some forge their salespeople will actually sell our product alongside their whole home heat pump systems because they're often asked, they're thinking about the whole home, but then often they're asked, would you like fries with that?

 

Would you also like a water heater? And then they're scrambling. Where am I going to find the appropriate contractor or the best product and everything? And so we are able to provide just a very seamless experience and integrate with their teams, and we install it. We handle electrical unless they want to handle the electrical.

 

So if you're a solar installer, you're a heat pump installer. You don't have plumbers on staff. We've got plumbers and we can come and we can work with you. And so we actually try to make it super easy for the homeowner as well as super easy for partners.



00:24:11.890 — 00:24:13.770 · Speaker 2

Yeah. So as my channel partner relationships.



00:24:13.850 — 00:24:16.930 · Speaker 1

Yeah, absolutely. A channel partner relationship. Yeah, yeah.



00:24:16.970 — 00:24:17.690 · Speaker 2

Now as you say, I.



00:24:17.690 — 00:25:44.450 · Speaker 1

Think that's where the products are obviously competitive. And that's where the go to markets are somewhat overlapping, competitive, but also complementary because there are folks in this room. We do run plumbing operations and are going to want to keep that business in-house, which is great, and that's fine.

 

And that's where our product is going to excel. And then there are places where we're going to compete for the my share and the business of other potential partners, and that's okay too. That's how business is supposed to work. We all know that, right? I think that to step back. The larger question is what's the opportunity and the interest and the appetite from the contractor population and the homeowner population to not do water heaters and not do heat pump water heaters the way that they have for a long time.

 

And to summarize it, the way that water heaters have worked for a century is when the water in the tank is called, or for a tankless unit when there's a rock, right. And the thesis of these two companies is that by understanding what's going to happen and what the home needs, this particular home, that you could do a better job, right.

 

You can do a better job in multiple ways. And what we're seeing from and I'll speak about us here, what we're seeing from our customer base, both the homeowners and the contractors, is that works like it's not that complicated in a concept to be like, hey, if it learns and adjusts to your home, it's going to do a better job, right?

 

It's going to customize this operation to your need. So I think that's some of the common pieces here.



00:25:45.090 — 00:25:47.250 · Speaker 2

Don't add there on the business model.



00:25:47.250 — 00:26:44.170 · Speaker 4

We're all talking about the same thing. But to take just one step back, the technology is one important piece, but almost as important, if not more important as it go to market and the market positioning, right? In our case, we decided we're not going to have a premium product with a lot of bells and whistles.

 

For example, our compressor is actually fixed speed. We do not have an electronic expansion valve. There's just nothing to it. It's extremely simple, so it's inexpensive. One of the or prouder moments from my solar thermal background is that we installed an awful lot of units across Massachusetts, and there was a lot of low income programs.

 

The rebate at the time was very progressive, and a large number of our installations were in modest homes in Western Massachusetts and stuff like that. For smart solar, our products, not expensive, were the same, if not slightly less than a conventional heat pump water heater. As such, we've got maybe five Housing Authority installations worth of smart solar also Cape Light Compact, which takes utility money and use it for weatherization and stuff like that.

 

We have probably 200 units installed for Cape Light Compact program, so we're not a premium product.



00:26:44.210 — 00:27:14.090 · Speaker 2

I want to get the audience a bit more involved knowing that there's a great group of contractors in here. Let's talk more about the value proposition for the contractor. Let's talk about what is unique from the install side for your different products. Are you doing inlet light on the top of the tank? Is it side?

 

Talk about how many it's super easy and to install commissioned units. How about the value competition for a contractor. Just kind of figure out what is in product out there, why they should go with it from under boss.



00:27:14.130 — 00:28:28.810 · Speaker 6

First, I'd say it starts with the product itself, right? You have to have a product that customers actually want. The way we look at it is there's 10 million water heaters installed in the United States every year, and only 2% of those are heat pump water heaters. What does that tell you? It tells you that homeowners are not chasing efficiency.

 

Our philosophy with Reservoir was we actually wanted to create a tankless gas killer, something that you'd feel confident pitching to a homeowner who has tankless gas. The first question my wife asked me when we were going to get a generic heat pump water heater was, are we going to run out of hot water?

 

And you don't want to piss off your customers and whatnot? And so our philosophy in developing the product was, first and foremost, how do we kill a tankless gas system? And that's why we only have a 50 gallon system. But you can get up to 150 gallons out of it. And so we're not just chasing efficiency numbers, right.

 

The other side, in terms of the installation, we actually have made the installation much, much easier. We've actually integrated the condensate pump. So you don't actually need a separate plug for it. You don't actually need to buy a separate device. We've actually seen some heat pump water heater installs where the contractor goes and installs the heat pump water heater with a 240 volt circuit.

 

And then is where the heck do I plug in the condensate pump? And they actually have to wire 120 volt plug for that thing. We also think that the best experience happens when you actually have full power when you're on a 240 volt circuit, but you don't always have an electrician available to actually help install it.



00:28:28.850 — 00:29:03.530 · Speaker 1

We actually engineered Reservoir so that you can install it at 120V. The goal is not for you to keep using Reservoir at 120V forever. It's that if the electrician can't show up for a week, they can show up later. What we actually found was in quite a few cases, you'd have a homeowner who definitely wanted to electrify and all these kinds of things.

 

Their water heater failed at the last minute and they couldn't get a heat pump water heater for a week, two weeks, something like that. So what we're able to do is we're able to respond very quickly, even if we can't coordinate the electrician right away. And so that's one of the things we're able to do. So we do quite a bit of emergency installs as well.



00:29:03.570 — 00:29:08.170 · Speaker 2

Crews anything on site. What's unique about startling was your price.



00:29:08.170 — 00:29:32.490 · Speaker 4

So our evaporators outside. So there's no getting around running refrigerant lines outside. But for this crowd in particular it's not difficult, especially if it's done in conjunction with mini splits, which happens very often. Our heat pumps 120 volt. It comes with the plug on it. You plug it into the wall, you can have 240 volt back up and we encourage people to do that if it's easy and there's room in the panel and stuff like that.

 

But we have a very large number of systems that are 120 volt only. That, of course, is possible by the fact that there's a larger tank.



00:29:32.530 — 00:32:30.000 · Speaker 1

Yeah. So we focused on, as I said before, on working with contractors. And so we make that installation as easy as possible in a number of different ways. So the screen is very communicative in a detailed way about what's going on. So what is the compressor doing. How is it starting up all of those different aspects.

 

And we've gotten a lot of feedback that gives the contractor greater confidence that the installation is going smoothly, and they're getting exactly what they need out of it. Where Side connect right now is that allows us to fully leverage the mixing valve that we've got installed and manage all of that.

 

And we found that particularly here in the northeast, that's working really well. You had a lot of basement installations. We are able to deliver units to our contractors within 24 hours everywhere that we're operating in the northeast. And for some of them who are moving multiple units, they're just buying in and storing them on site.

 

So they're keeping it two units, five units on site, and they're working through them. And that's allowing them to go and do same day installation. I can start cutting out the unit that is old, and the runner is going to bring the other unit from the office, and we're going to start that installation today.

 

So we're finding it works really well and enabling folks to get the product going and get it installed in the same day. But the day after is also really important, right? And so the remote monitoring that we're able to provide to our contractors has been a huge point of satisfaction. So we had a contractor say to us, I had to reset one of the major manufacturers, and I had to send a guy to drive two hours in order to do that on that heap up bar here.

 

That's something that we can do for them, and we can do that remotely so they don't have to roll that truck. And so making sure that the product is has incredibly high satisfaction for the homeowner in that you have the contractor is full understanding of what's going on. That's incredibly important over time that they're able to see that it doesn't have problems.

 

And I want to circle back to what I mentioned before, where I think it's important to acknowledge that there have been a better liability problems. And so by manufacturing here in the United States, by doing remote monitoring, by being all in on heat pump water heaters, we are relentlessly focused on making sure that every product, every unit is working incredibly well and that if anything does go wrong, that we're able to ensure an incredible level of service.

 

We think that's what's essential for the category to grow. Luke, you mentioned, rightfully so, that only 2% of water heaters sold in America today are heat pump water heaters. This is part of it. Like the contractors feeling confident in the product, walking in the door and saying, hey, yeah, I recommend that you get one that's part of it, right?

 

And so solving that problem, I think is part of what we're all trying to do as well. Yeah, I think that's a huge point. It's great that you guys provide great service to your contractors. And if you do work with us as a contractor and we do the install, the other side that we actually do is if something goes wrong, our team shows up to fix it.

 

And so it shows up to the homeowner. It takes a lot of that burden off you guys. So if that's a business model you want to work with, we'd love to chat.



00:32:30.040 — 00:32:38.240 · Speaker 2

So what question? I guess the great point I want to hear from you is we want to hear more of where you have. Are you like, huh? That sounds a little. Yeah.



00:32:38.400 — 00:32:39.280 · Speaker 4

Well, the predictive.



00:32:39.320 — 00:32:48.560 · Speaker 7

Technology that you have with the integration or you integrate into the utility grid through the API in Massachusetts, or is there something that you could do natural? Because I'm basically bishop.



00:32:48.760 — 00:33:10.360 · Speaker 1

Yeah. So we take in time of use rates for every customer. And we do that by just having them give us a bill or talking with them. Now Michigan has opt out time and use rates. You have a lot of time of use rates, is my understanding out there. So yes, we work with you. We work with the variable rates there. Yes, on split systems.

 

But you know what is your lowest amigo right.



00:33:10.600 — 00:33:11.200 · Speaker 7

I'm sorry.



00:33:11.240 — 00:33:12.240 · Speaker 1

What's your lowest game.



00:33:12.240 — 00:33:20.280 · Speaker 8

Give you what. So for example I come from my third campus. So we shut off the five of our random answers.



00:33:20.320 — 00:33:44.720 · Speaker 4

So a couple answers to your question. First question is there's no sensor on the evaporator at all, right. Second part of the answer is that Energy Star asked that question. They want to know what the lowest operating temperature is. We don't have one. Right? It'll keep going. The coefficient of performance and capacity will decrease.

 

We told them -20 Fahrenheit. But in fact, the heat pump will keep going all the way down to a coefficient performance 1.5, which is barely better than electrical resistance. But it doesn't stop.



00:33:44.720 — 00:33:46.680 · Speaker 2

Because they'll cut off for your sake. It was.



00:33:47.040 — 00:33:47.200 · Speaker 1

Cut.



00:33:47.240 — 00:33:51.800 · Speaker 4

There's no cutoff. There's no reversing cycle. It doesn't turn itself off and kick on to resistance heating.



00:33:52.120 — 00:33:53.360 · Speaker 8

Watch the macro.



00:33:53.400 — 00:33:54.000 · Speaker 4

Yes.



00:33:54.040 — 00:33:57.960 · Speaker 8

Okay. Do you have special rates for applications for small trailers?



00:33:58.080 — 00:34:35.879 · Speaker 4

Mobile homes are a tough one in general. Right? Or the A.W.. I just had a little competition to try to answer that question. They're trying to figure out how to get heat pump water heaters and to manufacture it housing. Right. Somebody entered a split design, not mine, and they won. But anyway, the point is that in a mobile home closet for water heater is generally very small, and sometimes the door opens from outside.

 

So it's a particular problem for heat pump water heaters. Not possible at all for an air source. Heat pump, water heater. We've done it on a couple of times for the Rise program on Cape Cod. So we do have an advantage in that it's just a tank, and the other stuff can be located elsewhere and the evaporator on the wall, but it's still it's not a fantastic use case for any type of heat pump water heater, unfortunately.



00:34:35.919 — 00:34:37.080 · Speaker 2

What other assets.



00:34:37.120 — 00:34:38.120 · Speaker 8

Do these have an effect.



00:34:38.120 — 00:34:38.560 · Speaker 1

On the heat.



00:34:38.560 — 00:34:39.280 · Speaker 2

Calculation of.



00:34:39.280 — 00:34:39.760 · Speaker 1

The home?



00:34:39.800 — 00:34:43.960 · Speaker 4

The split systems? No, no they don't. They're not exhausting the air. There's no fan to sit there in homes.



00:34:44.000 — 00:35:30.240 · Speaker 1

What about your competitors that are blowing you to them? Yeah. So the vast majority or let me put it this way, let me be specific. Over half of water heaters in American homes are in spaces that are outside the heating and cooling envelope of the building. Right. So here in the northeast, you got a ton of basements.

 

In the South, you have a lot that are in garages. So there you may see zero effect on the heating cooling loads of the home. There can be an effect if it's in the utility closet inside the envelope of the building in the south, you get a net benefit from the cooling and dehumidifier over the course of the season, right?

 

NREL has studied this before the name was changed. National lab of the Rockies. Now they've done extensive studies on this, and they found that the effect is actually very modest, so I'll summarize it that way.



00:35:30.280 — 00:35:52.960 · Speaker 2

And that for me, Manual J itself, in the latest version of Manual J, which was down in 2016, they vaguely mentioned that you can try to get into this or not, but there's nothing official in the protocol that you have to account for a heat pump water here in the space, but it's probably going to be something that will be more formally included in the next version of the package there.



00:35:53.000 — 00:35:58.200 · Speaker 1

Eric is just as qualified for this as as I am, but heating loads are already about.



00:35:58.200 — 00:35:59.320 · Speaker 7

30%.



00:35:59.360 — 00:36:03.880 · Speaker 1

Roughly oversize for what you need. Don't sweat the heating.



00:36:03.920 — 00:36:04.480 · Speaker 7

Don't be up.



00:36:04.480 — 00:36:08.320 · Speaker 1

Sizing heating equipment for a little water year. Thank you.



00:36:08.520 — 00:36:32.040 · Speaker 2

Not necessary. Yeah. The only time I've ever been worried about it is what is not installed in that basement space. Like Mike was saying, it's within a living part of the building. You've got a closet and you're drawing. It's a closet next to a small bedroom. That's where I might be more vocal and use Max to double check if I'm going to be using that condition.

 

Part of doing for. Actually.



00:36:32.400 — 00:36:54.760 · Speaker 1

I think what you need to think about it a little bit more than your heat load, because it's a relatively modest addition to the heat load, which you do need to think about it a little bit more is the makeup air. And just sitting in a space where you can get enough air, because at the end of the day, he pump has a heat exchanger where the more air you can pump through it.

 

If you're in a tiny closet, your efficiency is going to go through the floor. And so you need to figure out how you're going to vent it, put a louver door, things like that. So go ahead and follow up on that.



00:36:54.800 — 00:36:58.120 · Speaker 8

And that was going to lead to the next question for you know but your products.



00:36:58.120 — 00:36:58.800 · Speaker 1

Is.



00:36:58.800 — 00:37:01.840 · Speaker 8

Ducting. The product is yours. Can you duct your product.



00:37:02.080 — 00:37:05.640 · Speaker 1

We have ducting kits or better. Yeah. You can duct our product. Yep.



00:37:05.680 — 00:37:11.000 · Speaker 2

And what's buried Bruce you don't have to think about that because it's there. You just got it pulled on the outside.



00:37:11.040 — 00:37:13.120 · Speaker 8

What do you think that we found is.



00:37:13.440 — 00:37:15.640 · Speaker 2

Saying the expectations of the whole war.



00:37:16.360 — 00:37:23.640 · Speaker 8

For what a form is of equal quality. There's how many? We've had a number of cases where some was a bell, a oil.



00:37:23.640 — 00:37:24.080 · Speaker 2

Fire.



00:37:24.120 — 00:37:25.040 · Speaker 1

Water heater.



00:37:25.200 — 00:37:27.520 · Speaker 8

And they used to get partially in.



00:37:27.800 — 00:37:28.560 · Speaker 2

Hot water.



00:37:28.760 — 00:37:46.160 · Speaker 8

And then we put in keep on heater and all of a sudden it's oh how come I run out of water? And we tried with the largest boss in the tanker. Right. So we're putting the tank. Somebody has an oil buyer or a gas buyer, and we'll put in the biggest possibility.



00:37:46.240 — 00:37:46.880 · Speaker 2

To try.



00:37:46.880 — 00:38:14.720 · Speaker 8

It. They sure that the solvers are still getting enough hot water because they expect that. Oh, I've got a lot of water gear. And I turn faucet on it. It'll fill my tub. Six on driller. And then you either turn around and go out there and now we're running out of hot water. A couple of businesses where homeowners are just completely creeped out because they're take us.

 

So what we decided.



00:38:14.720 — 00:38:16.160 · Speaker 2

To do is actually.



00:38:16.400 — 00:38:24.440 · Speaker 8

Add a bath, is set the tanks a little bit higher temperature so that the adequate supply so that they don't actually run out of water.



00:38:24.480 — 00:40:13.510 · Speaker 1

Yeah. That's something that we specifically work to address. So Reservoir actually spends the first month in your house learning your behavior. And this is so that my wife doesn't get mad at me when he runs out of hot water. But basically, a heat pump is a slower way of heating the water. In an integrated system, it'll take 5 to 6 hours to heat up a 50 gallon tank, which means if you're using a reactive algorithm, you risk running out of hot water more, which is a lot of times why people end up over sizing their heat pump water heaters.

 

But I guess the way I like to think about it is you can get anywhere on time by walking as long as you leave on time. And so you're an early riser, so you shower at six in the morning. Every day. A Reservoir will learn your behavior and start heating at one in the morning. So you have plenty of hot water. You can actually put different settings on our adaptive algorithm so that you can say, I want to prefer efficiency.

 

So if you just really want to focus on saving energy at risk of sometimes running out of hot water, that's up to you. But it gives you a choice. Or you can favor more hot water. And so over time you can have higher output. Or it'll actually just adapt to your behavior and compensate for that. And that's actually one of the absolute biggest reasons we put predictive intelligence into it.

 

But we actually went beyond that. We're not purists that actually think that thou shalt never touch the electric resistance element. We actually have three electric resistance elements built into Reservoir. We have an inline booster heater built into it. So we can actually heat the marginal amount of hot water, as opposed to the two electric resistance elements that are inside the tank, where you try to heat the entire tank all at once.

 

We can heat just marginal amounts of hot water. So let's say you're in the shower. It's starting to get lukewarm. Play on my name really quick, but it's starting to get lukewarm. We can run the booster heater, make sure you finish your shower without destroying the efficiency of the whole system by trying to heat 50 gallons in a tank.

 

But that's actually a lot of the whole point of like why we have our adaptive algorithm, the extra resistance elements, but then we also have party mode, and so we can get 150 gallons out of it, even though the tank is just 50 gallons.



00:40:13.510 — 00:40:16.830 · Speaker 5

How long does it take to get 100 gallons? I've never really understood that set.



00:40:17.190 — 00:40:36.310 · Speaker 1

So our first our rating just on a basic level, is 75 gallons. If you actually go into party mode, we do what you're talking about with a mixing valve, so we can heat the water to about 150°F. But then because we also have that booster heater, we can get 150 gallons in on the scale of an hour and a half. So that's just that.

 

What don't you understand about it?



00:40:36.350 — 00:40:38.750 · Speaker 5

The time frame under which 150 gallons is delivered?



00:40:38.790 — 00:40:42.150 · Speaker 1

Oh, yeah. No, it's in the time that you would need 150 gallons.



00:40:42.150 — 00:40:42.670 · Speaker 2

With higher.



00:40:42.670 — 00:40:46.350 · Speaker 8

Temperature. Is it not going to be at risk of a more rapid degradation?



00:40:46.390 — 00:41:52.390 · Speaker 1

Yeah, I'm actually glad you asked that. So if you raise the temperature of a tank. So I think both of us are doing this where you have a mixing valve and you raise the temperature of the tank, you have faster corrosion at 150°F than you do at 120°F, and something like 6 to 7 times the corrosion rate. So what a typical heat pump, water heater, or a typical water heater will have is just a sacrificial anode rod, which is just a thicker magnesium.

 

It'll eat that before it eats the rest of the tank. What we actually have is we take some technology from the oil and gas or maritime industries. We have an electric anode rod. And so we inject a tiny amount of current. So we just cancel out the corrosion and we can actually manage that adaptively. So at 120°F, our current is slightly different than what it would be at 150°F.

 

And that's actually where you start getting into the idea of treating the system as a battery. Right. And so you can think about our system is you can jack it up to higher temperatures, lower it, and you go through more cycles. So we actually have more cycle life than other water heaters on the market. We've actually made it.

 

So the tank is almost certainly going to be the last thing that's going to fail on a Reservoir. Whereas on a typical water heater, it's the first thing that fails.



00:41:52.430 — 00:41:53.510 · Speaker 5

A couple of things to add on there.



00:41:53.510 — 00:43:11.510 · Speaker 1

So the point around increasing the temperature in the tank goes to the issue of if you set it and forget it to 150 gallons to maximize the capacity of the tank, you are increasing the thermal stress on the product on the tank. And so that's a real thing over time. And the way that it it's the corrosion is one failure dynamic.

 

But expansion and contraction is the second failure dynamic in the tank. And so one of the ways to think about that is how often are we going to do that? Right. So how often are we going to do that. So a couple of things about our tank. So we use a thicker steel than a normal. So it gives us a more robust tank. We're using a domestic manufacturer that makes a great tank 70 year old company.

 

And then the second thing is that we overheat the tank using Cala predictive intelligence. We overheat the tank to the extent that it makes sense to do so. Right. So if the family never needs it, we never do it. And if they need it only at 7:00 in the morning on Tuesdays and Thursday, then we'll only do it at 7:00 on Tuesdays and Thursdays.

 

Right. So you want to adjust the performance to the needs of the particular home, which is exactly what you're doing. And we also do it with the variable speed compressor. So we make sure that we get there in the most efficient way possible over time.



00:43:12.150 — 00:43:15.950 · Speaker 8

Section one how heavy is your project in guide? And I.



00:43:15.950 — 00:43:17.110 · Speaker 7

Ask curiously on face.



00:43:17.110 — 00:43:18.670 · Speaker 8

That the abundant brown.



00:43:18.670 — 00:43:20.750 · Speaker 7

Say dangerous event rain Overnight tanks.



00:43:20.750 — 00:43:21.070 · Speaker 8

Are



00:43:22.150 — 00:43:22.470 · Speaker 8

heavier.



00:43:22.470 — 00:43:24.669 · Speaker 7

Than the rest of the race, so getting it done



00:43:25.670 — 00:43:30.830 · Speaker 7

requires the beaver versus one kind of park dolly. The other question, isn't it? You come to.



00:43:30.830 — 00:43:30.950 · Speaker 8

The.



00:43:30.950 — 00:43:39.390 · Speaker 7

Ark. Are you guys looking to travel overseas, or will you guys be weekly with other contractors besides privateers with sovereignty works?



00:43:39.430 — 00:43:52.510 · Speaker 1

Yeah, we will absolutely be expanding. We're a young company as well, but we will. New York's on our priority list. The weight of our system is on us. You're not the guy taking it into the basement. We would be taking it into the basement. So when we get to New York, we should talk.



00:43:52.550 — 00:44:10.790 · Speaker 4

So our tanks are inherently lighter because there's not a heat pump bolted to the top of it. Right. We use Bradford White, makes our storage tanks right now. So the heaviest tank is 120 gallons and it's 210 pounds or something like that. As for New York, we have two installers, one installing distributor and one installer in New York right now.

 

So we're in New York in a couple of places.



00:44:10.790 — 00:44:14.710 · Speaker 1

Yeah, we have dozens of installations here. So we have products available there today.



00:44:14.750 — 00:44:30.670 · Speaker 8

So I love the few booby parts approach. But for you guys who have more predictive tools. Do you have any sensors that are tracking the failure of parts, especially with onboard pumps and things like that? Is there something predictive about, hey, this thing's about to go.



00:44:30.710 — 00:44:32.270 · Speaker 1

Down, or is that. Yeah. So the.



00:44:32.270 — 00:44:32.790 · Speaker 8

Fact.



00:44:32.790 — 00:45:00.550 · Speaker 1

We got feedback from some of our customers, not all of them, some of our customers who were more focused on the smart home, they wanted to see more. And so we just upgraded our app two weeks ago with what we call X-ray mode, where you can swipe in and you can see temperatures in the tank. You can see what the compressor is doing.

 

You can see the fan speed and all that. Now for us and for the contractors behind that is everything. So you've collected 450 million data points on our fleet today, and we could see all of it.



00:45:00.590 — 00:45:13.550 · Speaker 9

Yeah. What I would say we can do all that as well. We can see temperature at multiple levels of the tank. We can see like in a lot of heat pump water heaters. A compressor failure is an issue. And so it's just sitting there using electric resistance and the homeowner doesn't know about it. We know about it and we can.



00:45:13.550 — 00:45:37.030 · Speaker 1

Jump on that. What we actually do is we wanted to go beyond the water heater. We had sensors to Reservoir, but we had pressure sensors. So like I was saying, we can actually see if you have a leak in your broader plumbing system and then freeze detection and other stuff like that. And so I think there's a huge opportunity.

 

Our philosophy is you're going to replace your water heater anyway, so you should add some more capability to it. So some of those sensors help you service the system itself. But it actually helps you service the house. Right.



00:45:37.070 — 00:45:46.390 · Speaker 8

Anything that's straight up predictive like we're drawing more watts all of a sudden our compressor may be failing our pump maybe on its way out. Yeah.



00:45:46.390 — 00:46:26.950 · Speaker 1

There's different ways you can do it. We can have a team that just is obsessed with our product, and they can see if something is going on with your specific unit. We get alerts if there's a leak in your Reservoir. We get alerts. If there's if you let us, we get alerts if there's a leak in your house. And so you'll get it on your phone.

 

But we also we've told the customer, hey, you have absurdly high pressure in your house. In cities like Concord in Massachusetts. They have extremely high water pressure. One of our customers had a 110 psi in his house, and he didn't know about it. And that's not good for your plumbing system. And but there's something you can do about it.

 

It's called the pressure reducing valve. Right. And so we're able to spot a bunch of different things. So we're excited about the water heating component. But we're really excited about the broader plumbing security system component.



00:46:26.950 — 00:46:47.070 · Speaker 2

So sticking it there and connectivity we always ask this but I like some of the say more traditional ISO now out there. They rely on a home Wi-Fi for connecting and getting all this intelligence out to the cloud. And how are you guys landing that issue? Because it's a real problem when homeowners change the router and all.

 

But they up around Paragon. How do you manage that.



00:46:47.150 — 00:46:56.350 · Speaker 8

Yeah. So we've got Wi-Fi of course. And what we're seeing actually is that a 70% of all our installations are connected. We have a LoRaWAN.



00:46:56.350 — 00:46:56.510 · Speaker 1

As.



00:46:56.510 — 00:46:57.630 · Speaker 8

Well, and we're going to be.



00:46:57.630 — 00:46:58.270 · Speaker 1

Adding.



00:46:58.350 — 00:47:00.590 · Speaker 8

Next year. We're going to be adding additional.



00:47:00.630 — 00:47:01.870 · Speaker 1

Means of connectivity.



00:47:01.870 — 00:47:03.670 · Speaker 8

So our view is that.



00:47:03.670 — 00:47:05.230 · Speaker 1

Ultimately devices.



00:47:05.230 — 00:47:11.110 · Speaker 8

Like these there's going to be connectivity. Because the way we summarize it is connectivity is going to find a way.



00:47:11.110 — 00:48:05.470 · Speaker 1

And so Wi-Fi is working quite well for us now who got LoRaWAN as well. We're not doing as much of that. We'll do more of that in the future and we're going to add additional modalities. Yeah. Similarly, we use Wi-Fi. At the moment, 100% of our install base is actually connected. And I think this gets down to it's easier to connect something where the hardware and the software are well integrated, and then where you actually care about the connectivity.

 

But it's even more important when the homeowner actually cares about the connectivity. One of the great things about a smart device is that over time, it can actually get smarter and get smarter with software updates, but it can also get smarter as the install base grows. So we learn from the behavior of different homes and stuff like that.

 

And so when you have things like I'm away on vacation in January and my pipes might freeze, you want to be able to check your phone. And so you want to make sure that your Reservoir is actually connected. We do find in some cases we need to install Wi-Fi repeater, but at the end of the day, I think a lot of it comes to just caring about connectivity, but that the homeowner level as well as the installer level.



00:48:05.470 — 00:48:18.380 · Speaker 2

So they are again, close to the end. Here I'm going to take by you one more question. I want to give each of you a chance to share. Supposedly. Boss, would you do a touch up? Go ahead. This Simple, direct question of his carries with the project measures.



00:48:18.420 — 00:48:44.260 · Speaker 1

Of course, these two models right here have filters that need to be managed as well. So you all have a type of sensors for that as well, because I have a couple choir here in my room that they don't have a reminders or sensors to tell you a, a you need to address your filter. We've got a reminder on that as well, which is it's an easy for those of you.

 

I'm sure most people here have done it. It's a simple. Pull it out. Run it to the saying, put it back out. We didn't talk about batteries at all.



00:48:44.300 — 00:48:49.300 · Speaker 2

We got we got smart battery a little bit. But if you want to share so that you really got started. Oh, good.



00:48:49.380 — 00:50:45.420 · Speaker 1

I guess the other side of things is like one of the other reasons we started Reservoir. I imagine this is why you started Cala as well, is just this opportunity to treat a water heater as a thermal battery. So you can you don't care when we heat your water, we can heat it in three in the morning, four in the afternoon.

 

You care when you get your shower. Where that starts mattering is when you can integrate with time and use rates. As a homeowner, like in Groton, Massachusetts, the off peak energy rate is $0.05 a kilowatt hour. The on peak energy rate is $0.50 a kilowatt hour. You probably want to heat with that $0.05 a kilowatt hour rate.

 

And so it gives you a chance to actually save even more money. But then if you extrapolate that actually to the grid level, I think one of the most exciting things is if we do our jobs right, we get smart connected water heaters in a bunch of homes. It's actually the chance to help balance the grid without building more dirty power plants.

 

And so that's like the optimistic, hopeful side that I'm excited to end with. I agree with that. It is definitely part of why our company went on this journey, but I would bring it back by saying at the level of the contractor and the homeowner making it a thermal battery, making it storage allows us to move around in time, the energy use, but also when it's fully charged.

 

Right. It just goes back to the question from the gentleman over here, right. A typical he pulled water heater at 7:00 in the morning. If you look at the daily cycle, it reheated after the evening activities. Right. So then it got cool overnight. So when you hit the morning showers, regardless of its size.

 

It may even be nowhere close to actually being fully charged from a hot water perspective. And so the thermal battery concept absolutely applies at the grid, but it applies at like all levels of the product making sure there's hot water, saving money, integrating with solar and batteries in the home for those who have it, which is going to be more over time.

 

And then ultimately at the big level, the grid level as well, so that it's useful at every level and argue, hopefully benefits. Definitely. The homeowner with a contractor as well currently has some similar.



00:50:45.540 — 00:50:55.220 · Speaker 10

News rigs to like you mentioned, drawing where they have a four hour period for you to set the way their electric rates go.



00:50:55.260 — 00:51:08.100 · Speaker 1

Yeah, and it's going to be slow, but that's going to be everywhere. We should all be ready for that to come. It's three years. Five years, whatever. But a water heater lasts ten years, right? So it's going to come in the lifetime of the products being installed today.



00:51:08.140 — 00:51:10.540 · Speaker 2

Breeze cold is out here. Where are your final thoughts?



00:51:10.580 — 00:51:17.660 · Speaker 4

I think this was the storage conversation, so I'll be done one more time. A simpler, bigger tank. More heat pump. Heated water. Less electric resistance water.



00:51:17.700 — 00:51:19.940 · Speaker 2

All right, I think we're.



00:51:20.780 — 00:51:24.780 · Speaker 4

That's right. Yeah. We got twice the rebate in Massachusetts. SEC. Love splits.



00:51:25.380 — 00:51:28.740 · Speaker 2

Luke, Michael. Bruce, thank you so much. Give a round of applause for our panel.



00:51:33.380 — 00:51:37.940 · Speaker 2

Obviously. Please go out and ask questions. These guys are out here for the rest of the conference. Thank you so much for joining.



00:51:40.980 — 00:52:07.340 · Speaker 2

Thanks for listening to the Heat Pump Podcast. It is a production of Amply Energy and just a reminder that the opinions voice were those of our guests or us, depending on who was talking. If you like what you've heard and haven't subscribed, please subscribe in your favorite podcast platform. We'd love to hear from you, so feel free to reach out! You can reach us once again at hello@amply.energy. No .com just .energy. Thanks a lot.